Wednesday, April 24, 2024

Making Mass Changes to the Inspection Setup (QM) in Material Master

Procedure

  1. Choose Logistics -> Quality management -> Quality planning -> Logistics master data -> Material -> Inspection setup (Tcode: QA08 - Inspection Setup )

  2. Choose Inspection setup, Mass processing.

  3. Select the materials you want to process. You can make the selection by using the plant, material, the material type and the material class.

  4. Enter the required inspection type.

  5. Edit the following indicators:


Then 
Choose Execute

Appear a Screen like below screenshot. 

Check and Press Enter

Select All and Save





The screen for editing the inspection setup parameters in the material master is displayed.

  1. Edit the indicators and field entries and choose Continue.

If you set the Do not display material list indicator, the data for the chosen inspection type is changed immediately for all selected materials.

  1. If you did not set the Do not display material list indicator, select the materials from the list, for which you want to change the inspection type and choose Continue .

  2. Save your data.



No comments: